Slide Fuelman is an Antistatic hose with an excellent abrasion resistance and a very high tensile strength.
It is resistant to UV, ozone, fuels as well as weathering, hydrolysis and commonly used chemicals
ANTISTATIC HOSE FUELMAN

Slide Fuelman The “dual” strapped Fuelman exhibit less than 0,02 Ohm/m at operating pressure
Fuelman exceeds the conductivity spec. set by MIL-PRF-370J / 1999 standard, stating an electric resistance of maximum 4,9 Ohm/m.

INDUSTRIES

OIL AND GAS

FEATURES

  • This Antistatic hose has an excellent abrasion resistance and a very high tensile strength. It is resistant to UV, ozone, fuels as well as weathering / hydrolysis and commonly used chemicals. 
  • It has a positive buoyancy when operated in sea water or fresh water.
  • The hose meets the requirements set out in MIL-PRF-370J.
  • The hose is manufactured in compliance with ISO 9001:2015 quality management system.

DESIGN

  • Fuelman is a heavy duty Thermoplastic Polyurethane covered hose designed for transferring fuels, other liquid hydrocarbons or to be used as a general purpose Antistatic hose.
  • The lay flat hose is designed using the state of the art “extrusion through the weave” technology, ensuring a very good bonding between cover and lining the textile weave.
  • The antistatic property is ensured by dual longitudinal cooper wire straps attached to the hose body and which are connected to the end coupling. 

ADVANTAGE

  • Low weight.
  • Easy deployment and retrieval.
  • Less storage needed – Stored on reels or flaked in containers
  •  Long lengths + 200m
  • Easy to access the copper wires for safe installation

Slide MILITARY REFINERIES BULK REFUELING HYDRAULIC FRACTURING SOME APPLICATIONS

TECHNICAL DATA

FUELMAN STANDARD

INTERNAL DIAMETER WALL THICKNESS WEIGHT BURST PRESSURE TENSILE STRENGTH
Inch mm Inch mm Lbs / Ft Kg / m Psi Bar x 1000 Lbs Tons
1 1/2 38,0 + 1,6 0,07 2,1 0,20 0,30 655 45 5,8 2,8
2 51,0 + 2,0 0,09 2,2 0,29 0,44 655 45 7,6 3,5
2 1/2 65,0 + 2.0 0,09 2,3 0,36 0,58 610 42 9,1 4,3
3 76,0 + 2.0 0,09 2,4 0,47 0,75 610 42 10,7 5,0
4 102,0 + 2,5 0,12 2,7 0,72 1,07 520 36 23,1 10,8

NOTE: Maximum working pressure is 25% of listed Burst pressure, i.e. SF 4:1. Ensure that the end coupling is designed for this working pressure. The Burst Pressure values listed are measured on a straight lying, free expanding hose according to ISO 1402. Tensile strength is calculated values – Efficiency factor is 0.7. Operating Temperature range. -50 to + 50 ºC(-58ºF to +122ºF). Recommended operating pH range: 5 to 9.

INTERNAL DIAMETER WALL THICKNESS WEIGHT BURST PRESSURE TENSILE STRENGTH
Inch mm Inch mm Lbs / Ft Kg / m Psi Bar x 1000 Lbs Tons
6 152 + 3,0 0,15 3,7 1,34 2,00 650 45 44,0 21,0
7 178 + 3,0 0,16 4,0 1,61 2,40 650 45 70,0 31,8
8 203 + 3,0 0,17 4,2 2,15 3,20 610 42 81,5 37,0
10 254 + 3,0 0,17 4,3 2,73 4,10 520 36 101,2 46,0
12 305 + 5,0 0,18 4,5 3,38 5,05 435 30 120,0 54,5 
  • (Dimensions 1 1/2” to 4” only on request)
  • (Minimum order quantity might apply / Delivered in up to 200 meters sections)

NOTE:   Maximum working pressure is 25% of listed Burst pressure, i.e. SF 4:1. Ensure that the end coupling is designed for this working pressure. The Burst Pressure values listed are measured on a straight lying, free expanding hose according to ISO 1402. Tensile strength is calculated values – Efficiency factor is 0.7. Operating Temperature range. -50 to + 50 ºC  (-58ºF to +122ºF). Recommended operating pH range: 5 to 9.

FUELMAN EXTRA

INTERNAL DIAMETER WALL THICKNESS WEIGHT BURST PRESSURE TENSILE STRENGTH
Inch mm Inch mm Lbs / Ft Kg / m Psi Bar x 1000 Lbs Tons
2 51 + 2,0 0.13 3,2 0,47 0,7 900 62 10,1 4,6
3 76 + 2,0 0.13 3,3 0,67 1,0 900 62 17,6 8,0
4 102 + 2,5 0.15 3,8 1,07 1,6 900 62 30,8 14,0
6 152 + 3,0 0.17 4,4 1,68 2,5 850 58 50,6 23,0
  • (Minimum order quantity might apply / Delivered in up to 200 meters sections)

NOTE:   Maximum working pressure is 25% of listed Burst pressure, i.e. SF 4:1. Ensure that the end coupling is designed for this working pressure. The Burst Pressure values listed are measured on a straight lying, free expanding hose according to ISO 1402. Tensile strength is calculated values – Efficiency factor is 0.7. Operating Temperature range. -50 to + 50 ºC  (-58ºF to +122ºF). Recommended operating pH range: 5 to 9.

FUELMAN EXTREME

INTERNAL DIAMETER WALL THICKNESS WEIGHT BURST PRESSURE TENSILE STRENGTH
Inch mm Inch mm Lbs / Ft Kg / m Psi Bar x 1000 Lbs Tons
4 110,5 + 2,0 0,17 4,2 1,16 1,73 2500 172 178 80
5 135,5 + 2,0 0,18 4,5  1,64 2,45 2500 172 218 98
  • (Only on request)

NOTE:   Maximum working pressure is 25% of listed Burst pressure, i.e. SF 4:1. Ensure that the end coupling is designed for this working pressure. The Burst Pressure values listed are measured on a straight lying, free expanding hose according to ISO 1402. Tensile strength is calculated values – Efficiency factor is 0.7. Operating Temperature range. -50 to + 50 ºC  (-58ºF to +122ºF). Recommended operating pH range: 5 to 9.